Hose & Ducting for HVAC and Ventilation Contractors

Hose & Ducting for HVAC and Ventilation Contractors

HVAC and ventilation contractors buy a lot of things that are not hose — fans, grilles, rigid spiral, controls. But almost every install and service visit also needs a few metres of flexible duct: the connector from a ceiling fan to the spigot, the extraction drop to a workshop machine, the hot-air run off a process heater. Get that flexible link wrong and it is the first thing to sag, crush, split or cook, and the callback lands on you rather than the fan manufacturer.

This guide is written for buyers who stock flexible duct for installation crews and service vans. It covers the four flexible lines in our flexible ducting range, what each one is genuinely good for, the real temperature and size limits from our spec sheets, and how to build a sensible van and stores range without tying cash up in coils that never move. With the heating season under way, it is also a good time to check the hot-air lines are on the shelf before the breakdown calls start.

Aluminium, PU, silicone & PVCBores from 19mm to 200mmSilicone duct to +310°CPU duct in 10m & 20m coils£500 min order (ex VAT)Same-day collection, Mirfield

Four Flexible Duct Types, Four Different Jobs

Aluminium air ducting
The everyday connector for domestic and light commercial extract: kitchen and bathroom fans, short ceiling-void runs and hot-air extraction. Lightweight, easy to form round obstructions and cut to length on site. Stocked in 76, 102, 125 and 150mm bores — see our aluminium air ducting.
Polyurethane (PU) ducting
Clear, abrasion-resistant duct with a copper-coated spring steel helix. The choice for dust and fume extraction drops in workshops, joinery shops and plastics plants, where chips and granules would scour a foil duct. The clear wall lets you see a blockage forming. Browse our polyurethane ducting.
Silicone 2-ply ducting
Coated fibreglass inner, steel wire helix and silicone jacket. Rated −70 to +310°C continuous (peak +350°C), so it belongs on industrial dryers, process heaters and high-temperature fume extraction where other ducts soften or char. See our silicone 2-ply ducting.
PVC corrugated hose
Not an air duct for main runs, but a useful van item for light-duty drainage and clean-water transfer: crush-resistant, flexible, supplied in 30m and 50m coils from 19mm to 51mm bore from 19mm to 51mm bore. More detailmdash; see our PVC corrugated hose. More detail in our guide to PVC corrugated and ducting hose types.

The Numbers That Matter

Specify by internal diameter to match the spigot, then check temperature and the environment. These are the figures from our current product data; reading a hose spec sheet explains how to read them.

Aluminium air ducting 76mm ID in 2m and 4m lengths; 102mm, 125mm and 150mm ID in 4m lengths. Heat- and corrosion-resistant, for ventilation and hot-air extraction.
PU ducting 38mm to 200mm ID (38, 50, 65, 80, 100, 125, 150, 160, 180, 200mm). 10m or 20m coils depending on bore. Approx. 0.4mm wall. −40 to +90°C (short-term +125°C). Resistant to oils, fuels and many chemicals.
Silicone 2-ply ducting 25mm to 200mm ID, 4m lengths (76mm also in 8m). −70 to +310°C, peak +350°C. Black as standard; red, blue and grey in popular mid sizes.
PVC corrugated hose 19mm to 51mm ID in 30m and 50m coils. −10 to +65°C (peak +70°C). Black, clear, or clear with a blue rib.
Fixings Ducting is clamped onto spigots — stock matching clamps and clips in the same bores. our clamp guide covers which type suits which joint.
Rule of thumb: foil for clean air, PU for anything that carries dust or chips, silicone for anything hot. Most premature duct failures we hear about are the right bore in the wrong material.

Building a Van and Stores Range

1
List the spigot sizes you actually fit
Pull a year of jobs and count the bores. Most ventilation crews find 100mm-class and 125mm-class connectors dominate, with 150mm close behind. Stock deep on those and order the outliers against the job.
2
Split by environment, not just size
Keep a domestic extract kit (aluminium), a workshop extraction kit (PU) and a small amount of silicone for the hot jobs. One material across every application is where callbacks come from.
3
Match clamps to every bore
A coil of duct with no clamps for that bore is a wasted trip. Build the clamp order from the same size list so each van carries complete connections.
4
Combine into one order
Ducting, clamps, couplings and any hose the rest of the business uses can go on the same £500 order — worth reading on consolidating suppliers.

Where Our Ducting Gets Used

Domestic & light commercial ventilation
Aluminium connectors for extract fans, cooker hoods and short ceiling-void runs, bought in 4m lengths to suit a single install.
Workshop & dust extraction
PU drops from extraction ducting to machines in joinery, plastics and fabrication shops. If a site needs anti-static duct, ask the team before ordering rather than assuming a standard coil will do.
Industrial heating & drying
Silicone 2-ply on dryers, process heaters and hot-air lines, where operating temperatures rule out foil and PU.
Maintenance contracts
FM and service contractors holding a mixed shelf of all three, so a reactive visit is a one-trip fix rather than a return visit.

Every Hoses UK order is settled on pro-forma before dispatch or collection: no credit checks, no application, and in return sharper wholesale pricing and deeper stock on the lines contractors use every week. Orders ship free over £500 to mainland UK, Express next-day is available at checkout, and stocked lines can be collected the same day from Mirfield. New trade customers also take £25 off their first order. If you need a duct length, bore or assembly that is not on the site, the team can talk through bespoke options and quote a lead time.

Stocking vans for a ventilation team, or need a hot-air duct by tomorrow? Open a trade account, or talk to the team about bores, lengths and quantities.

Open a Trade AccountTalk to the TeamBrowse the range

Frequently Asked Questions

Which flexible ducting should I use for workshop dust extraction?
Polyurethane (PU) ducting. Its clear, abrasion-resistant wall and spring steel helix stand up to chips, dust and granules far better than foil duct, and you can see a blockage forming. We stock 38mm to 200mm bores in 10m and 20m coils.
What ducting handles high temperatures?
Silicone 2-ply ducting is rated from −70 to +310°C continuous, with a peak of +350°C, which suits industrial dryers, process heaters and hot fume extraction. PU ducting is rated to +90°C (short-term +125°C).
What sizes of aluminium air ducting do you stock?
76mm ID in 2m and 4m lengths, plus 102mm, 125mm and 150mm ID in 4m lengths.
Is there a minimum order for ducting?
Yes, the £500 minimum (ex VAT) applies across the whole basket, so ducting can be combined with clamps, couplings and hose on one order. Orders over £500 ship free to mainland UK.